- The weather station should be located in an open area where the equipment can be easily accessed. There should be no significant obstacles around the site where the weather station is located (large houses, groups of trees).
- Under no circumstances should the weather station be installed close to highly heated surfaces, e.g. roofs with roofing felt.
- The installation site should be chosen in an area that is typical of the surrounding area and does not differ from the surrounding area in any way in terms of heat and moisture exchange.
- The weather station must not be located in the shade.
- The weather station shall be installed above the ground. The installation height should be at least 2 m above the ground.
- DC supply voltage, V
- 12
- Current consumption at 12 V DC, not more, mA
- 30
- Measuring range of relative air humidity, %
- from 1 to 100
- Limits of permissible absolute error of relative air humidity measurements, %
- ± 3
- Average MTBF, h
- 10000
- Service life, years
- 8
- Interface (to be determined when ordering)
- RS-485 or RS-232
- Mounting
- on stainless steel mast for Ø 60 – 76 mm
- Degree of enclosure protection
- IP66
- Case Material
- Plastic
- Diameter, mm
- 140
- Length, mm
- 180
- Weight, including mast mounting, excluding connecting cable, kg
- 0,8
- Air temperature, °C
- from -50 to +60
- Relative humidity, %
- from 0 to 100
- Atmospheric pressure, hPa
- from 300 to 1200
- Storage conditions
- Humidity from 0% to 100%, Temperature from -50 to +70°C
- Measured parameters
- Air temperature, Relative humidity of the air