- No maintenance required.
- Easy installation, no special setting required.
- Using semiconductor method to monitor volatile organic substances (VOC).
- Small volume, light weight.
- Low power, high accuracy.
- Air temperature, °C
- from -50 to +80
- Air temperature resolution, °C
- 0,1
- Air temperature error, °C
- ± 0.2
- Air humidity, %Rh
- from 0 to 100
- Air humidity resolution, %Rh
- 0,1
- Air humidity error, %
- 2
- Wind speed, m/s
- from 0 to 60
- Wind speed resolution, m/s
- 0,1
- Wind speed accuracy, m/s
- ± 0.3 or 3%
- Wind speed measurement method
- Ultrasonic sensor
- Wind direction, °
- from 0 to 360
- Wind direction resolution, °
- 1
- Wind direction error, °
- ±3
- Atmospheric pressure, hPa
- from 10 to 1200
- Atmospheric pressure resolution, hPa
- 0,1
- Atmospheric pressure error, hPa
- 0,3 (25°C)
- Volatile Organic Compounds measurement, CO
- from 0 to 1000ppm
- Volatile Organic Compounds detection limit, CO, ppb
- 0,1 (electrochemical)
- Volatile Organic Compounds measurement, NO2, O3 and NO
- from 0 to 20 ppm
- Volatile Organic Compounds detection limit, NO2, O3 and NO, ppb
- 5 (electrochemical)
- Volatile Organic Compounds measurement, SO2, H2S and VOC
- from 0 to 100 ppm
- Volatile Organic Compounds detection limit, SO2, H2S and VOC, ppb
- 5
- Volatile Organic Compounds measurement, PM2.5 and PM10
- from 0 to 1000ug/m3
- Volatile Organic Compounds detection limit, PM2,5 and PM10, ug/m3
- 0,3
- Volatile Organic Compounds accuracy, PM2,5 and PM10
- ±15% or ±10μg/m3, laser scattering.
- Operating Temperature, °C
- from -20 to +60
- Power supply, V
- 12